King of Chemicals Manufacturers
Specifications, Properties, Uses, SDS of Phosphorous acid or Orthophosphorous acid or Phosphonic Acid Manufacturer Supplier Exporter Wholesale & Small Packs, CAS Number 13598-36-2 or 10294-56-1 or 14901-63-4.
King of Chemicals has several associated companies having accreditations like cGMP, GLP - FDA Approved Good Manufacturing Practice and Good Laboratory Practice of WHO standard, ISO-9001, ISO-14001, ISO/IEC 17025, ISO ISO-45000, HACCP, FSSC 220000, FSSAI, "REACH" Registered, Kosher & Halal Certified. e-CTD and DMF support can be made available if needed. We offer USP NF BP Ph Eur EP IP JP Analytical Reagent FCC Food Grade Chemicals & Nutraceuticals. Muby Chem Pvt. Ltd. is a several decades old group of companies, engaged in manufacturing, supplying, distributing, wholesale supplies of Phosphorous acid or Orthophosphorous acid Phosphonic Acid for actual users, including retail or small pack supplies for research and development work.
We supply fine and speciality chemicals, pharmaceutical excipients, mineral fortifiers in chemically pure, analytical reagent grade, IP BP USP Ph Eur EP JP and other pharmaceutical grade monograph including FCC Food grade chemicals and Nutraceuticals at best prices. We and/or our associated units have all the facilities to supply as per cGMP standard observing good manufacturing practice and good laboratory practice. We can assure low microbial count and also offer a test certificate for the same. We maintain warehouses across USA, India, and UAE. Our group exports to USA, Canada, Mexico, Argentina, Brazil, Chile, Korea, Malaysia, Thailand, Indonesia, Europe, and several other parts of the world. We supply in wholesale container loads to small pack of few grams. Solid products may be specified for it size and shape as desired by the buyer.
Phosphorous acid or Orthophosphorous acid Phosphonic Acid CAS Number 13598-36-2 or 10294-56-1 or 14901-63-4For Properties Specifications Uses of Phosphorous acid or Orthophosphorous acid Phosphonic Acid Click Properties, Specifications, Uses, Price, Process of Phosphorous acid or Orthophosphorous acid Phosphonic Acid Manufacturer.
For For SDS MSDS Sheet of Phosphorous acid or Orthophosphorous acid Phosphonic Acid Click SDS Safety Data Sheet MSDS Sheet of Phosphorous acid or Orthophosphorous acid Phosphonic Acid Manufacturer.
The Properties, Specifications, Monograph and Uses of Phosphorous acid or Orthophosphorous acid Phosphonic Acid:
Phosphorous acid (H3PO3), also called orthophosphorous acid, one of several oxygen acids of phosphorus, used as reducing agent in chemical analysis. It is a colourless or yellowish crystalline substance with a garlic-like taste. Phosphorous acid or Orthophosphorous acid Phosphonic Acid is used in the production of basic lead phosphonate PVC stabilizer. Also used as a strong reducing agent and in the production of raw materials of phosphorous acid, synthetic fibres and organophosphorus pesticides etc. It used in the production of high-efficient water treatment agent amino trimethylene phosphonic acid.
The MSDS-SDS Hazard Statement of Phosphorous acid or Orthophosphorous acid Phosphonic Acid:
Phosphorous acid or Orthophosphorous acid or Dihydroxyphosphine oxide or Phosphonic Acid SDS Safety Data Sheet
MSDS Sheet 19-Apr-22Section 1: Product Identification
Product Name & Other Names: Phosphorous acid or Orthophosphorous acid or Dihydroxyphosphine oxide or Phosphonic Acid.
CAS No.: 13598-36-2 or 10294-56-1 or 14901-63-4
EINECS EC Number: 237-066-7 or 233-663-1
Molecular Weight: 81.99
Chemical Formula: H3PO3
Relevant uses of the substance and uses advised against: Laboratory chemicals, Manufacture of substances. For Industrial use.
Details of the supplier of the safety data sheet: As per letter head.Section 2: Hazard Identification
GHS, Globally Harmonized System Classification in accordance with 29 CFR 1910
Classification according to Regulation (EC) No 1272/2008Corrosive to Metals (Category 1), H290
Acute toxicity, Oral (Category 4), H302
Skin corrosion/irritation (Category 1A, B, C), H314Labeling according to Regulation (EC) No 1272/2008
GHS Label Elements
CorrosiveSignal Words: Danger
Hazard statements:
H290: May be corrosive to metals.
H302: Harmful if swallowed.
H314: Causes severe skin burns and eye damage.Precautionary statements:
P234: Keep only in original container.
P260: Do not breathe dust/fume/gas/mist/vapors/spray.
P264: Wash … thoroughly after handling.
P280: Wear protective gloves/protective clothing/eye protection/face protection.
P312: Call a POISON CENTER or doctor/physician if you feel unwell.
P362: Take off contaminated clothing and wash before reuse.
P301+330+331: IF SWALLOWED: Rinse mouth. Do NOT induce vomiting.
P301+312: IF SWALLOWED: Call a POISON CENTER or doctor/physician if you feel unwell.
P303+361+353: IF ON SKIN (or hair): Remove/Take off immediately all contaminated clothing. Rinse skin with water/shower.
P305+351+338: IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses if present and easy to do – continue rinsing.Section 3: Composition / Information on Ingredients
Product Name & Other Names: Phosphorous acid or Orthophosphorous acid or Dihydroxyphosphine oxide or Phosphonic Acid.
CAS No.: 13598-36-2 or 10294-56-1 or 14901-63-4
EINECS EC Number: 237-066-7 or 233-663-1Section 4: First Aid Measures
Always seek medical attention after first aid measures are provided.
Eye Contact: Check for and remove any contact lenses. In case of contact, immediately flush eye with plenty of water for at least 15 minutes. Cold water may be used. Get medical attention immediately.
Skin Contact: Immediately flush skin with plenty of water for at least 15 minutes while removing contaminated clothing and shoes. Call a physician, immediately. Wash clothing before reuse.
Ingestion: If swallowed, do not induce vomiting unless directed to do so by medical personnel. Never give anything by mouth to and unconscious person. Loosen tight clothing such as a collar, tie, belt, or waistband. Get medical attention immediately.Section 5: Fire Fighting Measures
Flash Point: NA
Fire Extinguishing Media: Adapt extinguishing media to the environment. Use water spray, alcohol-resistant foam, dry chemical, or carbon dioxide. No limitations of extinguishing agents are given for this substance.
Special Fire Fighting Procedures: Wear self-contained breathing apparatus for firefighting if necessary.
Hazardous combustion products: Oxides of phosphorous.
Extinguishing Media Not recommended: Avoid using solid water jet as it may scatter the fire.
Special Information: In the event of a fire, wear full protective clothing and NIOSH-approved self-contained breathing apparatus with full face piece operated in the pressure demand or other positive pressure mode. At elevated temperatures under fire conditions, it may produce toxic or irritating fumes. Fire-extinguishing work is done from the windward and the suitable fire-extinguishing method according to the surrounding situation is used. Uninvolved persons should evacuate to a safe place.Section 6: Accidental Release Measures
Personal precautions, protective equipment, and emergency procedures: Ventilate area of leak or spill. Avoid breathing dust/fumes/gas/mist/vapors/spray. Use individual protective equipment (waterproof boots, suitable protective clothing, safety glasses, etc.). Do not approach facing the wind. Do not touch the spilled material. Eliminate any ignition sources.
Environmental precautions: Do not let the product enter drains, soil, or water sources.
Methods and materials used for containment cleanup procedures and Storage: Contain spilled material. Cover with an inert, non-combustible absorbent material, (e.g., sand, earth, diatomaceous earth, vermiculite). Vacuum or sweep-up and remove to an approved disposal container. Small quantities of liquid spill may be neutralized with acid solution. Wash away neutralized product with plentiful water. Clean contaminated surfaces with an excess of water. Take collected spill to manufacturer/competent authority.Section 7: Handling and Storage
Precautions for safe handling: Apply according to good manufacturing and industrial hygiene practices. Ensure proper ventilation. Wash thoroughly after handling. Do not drink, eat, or smoke while handling. Avoid contact with skin, eyes, and clothing. Minimize dust generation. Avoid breathing dust/fumes/gas/mist/vapors/spray. Avoid contact with eyes, skin, and clothing. Keep container tightly closed. Use individual protective equipment (waterproof boots, suitable protective clothing, safety glasses, etc.). Prevent any contact with hot surfaces.
Conditions for safe storage, including any incompatibilities: Store in cool, dry, and ventilated area away from heat sources and protected from sunlight in tightly closed original container. Keep air contact to a minimum. Store protected from heat, sparks and ignition sources and incompatible materials. Do not store with incompatible materials like strong oxidizing agents, strong bases, metals.Section 8: Exposure Controls / Personal Protection
Components with workplace control parameters: This product does not contain any hazardous materials with occupational exposure limits established by the region specific regulatory bodies.
Engineering Controls Ventilation required: It should be handled or transferred in an approved fume hood or with adequate ventilation.
Ventilation System: A system of local and/or general exhaust is recommended to keep employee exposures as low as possible. Local exhaust ventilation is generally preferred because it can control the emissions of the contaminant at its source, preventing dispersion of it into work area.
Personal Respirators (NIOSH Approved): For conditions of use where exposure to dust or mist is apparent and engineering controls are not feasible, a particulate respirator may be worn.
Skin Protection: Wear protective gloves and clean body-covering clothing.
Eye Protection: Use chemical safety goggles and/or full face shield where dusting or splashing of solutions is possible. Maintain eye wash fountain and quick-drench facilities in work area.
Other Control Measures: Maintain good housekeeping in work area. Dust deposits on floors and other surfaces may pick up moisture and cause the surfaces to become slippery and present safety hazards. Handle in accordance with good industrial hygiene and safety practice.Section 9: Physical and Chemical Properties
Appearance and Physical State: White solid, deliquescent.
Odor: Odorless.
Odor threshold: Not available.
pH: 1-1.5 at 50gm/liter
Relative density: around 1.65
Melting Point: 72C to 74C.
Boiling Point: 200C decomposes.
Flash point: Not available.
Auto-ignition temperature: Not available.
Decomposition temperature: Not available.
Upper/lower flammability or explosive limits: Not available.
Vapor Pressure (mm Hg): Not available.
Vapor density: Not available.
Evaporation rate: Not available.
Flammability (solid, gas): Not available.
Partition coefficient: n-octanol/water: Not available.
Solubility in Water: Soluble in water and ethanol.
Viscosity: Not available.
Molecular Weight: 81.99
Chemical Formula: H3PO3Section 10: Stability and Reactivity
Stability: It is stable under ordinary conditions of use and storage.
Materials to Avoid (Incompatibility): Strong oxidizing agents, strong bases, metals, direct sunlight. air contact, moisture.
Hazardous Decomposition Products: Thermal decomposition may produce toxic fumes of phosphorus oxides and/or phosphine.
Hazardous Polymerization: Will not occur.Section 11: Toxicological Information
Results of component toxicity test:
LD50 Oral (rat): 1895 mg/kg
Carcinogenicity: This product is not classifiable as to its carcinogenicity based on its IARC, ACGIH, NTP, or EPA classification.
Mutagenic Effects: Not available.
Teratogenic Effects: Not available.
Developmental Toxicity: Not available.
Reproductive Effects: No information available.Section 12: Ecological Information
Toxicity to fish: LC50: 6980 - 9784 mg/L, 96h static (Brachydanio rerio)
Toxicity to daphnia and other aquatic invertebrates: static test EC50 - Daphnia magna (Water flea) - > 1.000 mg/l - 48 h
Results of PBT and vPvB assessment: This substance/mixture contains no components considered to be either persistent, bioaccumulative and toxic (PBT), or very persistent and very bioaccumulative (vPvB) at levels of 0.1% or higher.Section 13 Disposal Considerations
State and local laws governing disposal of materials can differ. Ensure proper disposal compliance with proper authorities before disposal.
Section 14: Transportation Information
Land Transport DOT USA, TDG Canada & ADR/RID Europe :
Proper shipping name: PHOSPHOROUS ACID
Hazard Class: 8, Packaging group: III
UN Number: UN12834
Air Transport ICAO/IATA:
Proper shipping name: PHOSPHOROUS ACID
Hazard Class: 8, Packaging group: III
UN Number: UN12834
Sea Transport IMO/IMDG:
Proper shipping name: PHOSPHOROUS ACID
Hazard Class: 8, Packaging group: III
UN Number: UN12834Section 15: Regulatory Information
USA:
SARA Section 311/312: See Section 2.
California Proposition 65: Not applicable.Section 16: Other Information
DISCLAIMER: The information and recommendations set forth herein (hereinafter "Information") are presented in good faith and believed correct as of the date hereof. It is compiled from various sources, and it is not necessarily all inclusive nor fully adequate in every circumstance. In addition, these suggestions should not be confused with nor followed in violation of applicable laws, regulations, rules, or insurance requirements applicable. This MSDS sheet is intended only as a guide to the appropriate precautionary handling of the material by a professionally trained person using this product. Individuals receiving the information must exercise their judgment in determining its appropriateness for a purpose.
Phosphorous acid or Orthophosphorous acid Phosphonic Acid Manufacturers, Suppliers, Exporters, Wholesalers:
King of Chemicals manufacturers
Plot No. 2900/46&47 + 2900/163to167, GIDC, Ankleshwar, Dist. Bharuch, India
India, USA, UAE
TEL: (Office) 91-22-23774610, 91-22-23723564e-mail: info@kingofchemicals.com
Copyright and Usual Disclaimer is Applicable --- October 28, 2024
If I give you “My Word” Nobody can undo it.
If I sign an “Agreement” my Lawyer will undo itOur products are for industrial and laboratory use only. The user must test the material before use. We are not dispensing chemists or druggist and do not offer over the counter type (OTC) products for medical use by individuals.
We and our associates manufacture pure chemicals surpassing Monograph Specifications of Analytical Reagent Standards, British & European Pharmacopoeia BP Ph Eur EP Standard, US Pharmacopoeia USP NF Standard, Indian Pharmacopoeia IP Standard, Japan Pharmacopoeia JP Standard, FCC Food Grade Standard.Hydrated Manganese Glycero-phosphate
Phosphoric Acid or Orthophosphoric Acid