King of Chemicals Manufacturers
Specifications, Properties, Uses, SDS of Lactobionic Acid USP NF BP Ph Eur Grade Manufacturer Supplier Exporter Wholesale & Small Packs, CAS Number 96-82-2.
King of Chemicals has several associated companies having accreditations like cGMP, GLP - FDA Approved Good Manufacturing Practice and Good Laboratory Practice of WHO standard, ISO-9001, ISO-14001, ISO/IEC 17025, ISO ISO-45000, HACCP, FSSC 220000, FSSAI, "REACH" Registered, Kosher & Halal Certified. e-CTD and DMF support can be made available if needed. We offer USP NF BP Ph Eur EP IP JP Analytical Reagent FCC Food Grade Chemicals & Nutraceuticals. Muby Chem Pvt. Ltd. is a several decades old group of companies, engaged in manufacturing, supplying, distributing, wholesale supplies of Lactobionic Acid for actual users, including retail or small pack supplies for research and development work.
We supply fine and speciality chemicals, pharmaceutical excipients, mineral fortifiers in chemically pure, analytical reagent grade, IP BP USP Ph Eur EP JP and other pharmaceutical grade monograph including FCC Food grade chemicals and Nutraceuticals at best prices. We and/or our associated units have all the facilities to supply as per cGMP standard observing good manufacturing practice and good laboratory practice. We can assure low microbial count and also offer a test certificate for the same. We maintain warehouses across USA, India, and UAE. Our group exports to USA, Canada, Mexico, Argentina, Brazil, Chile, Korea, Malaysia, Thailand, Indonesia, Europe, and several other parts of the world. We supply in wholesale container loads to small pack of few grams. Solid products may be specified for it size and shape as desired by the buyer.
Lactobionic Acid CAS Number 96-82-2For Properties Specifications Uses of Lactobionic Acid Click Properties, Specifications, Uses, Price, Process of Lactobionic Acid Manufacturer.
For For SDS MSDS Sheet of Lactobionic Acid Click SDS Safety Data Sheet MSDS Sheet of Lactobionic Acid Manufacturer.
The Properties, Specifications, Monograph and Uses of Lactobionic Acid:
CAS Number: 96-82-2, Molecular Weight: 358.30, Chemical Formula: C12H22O12, EINECS EC Number: 202-538-3, H S Code 29329900 or 29181190
Lactobionic acid (4-O-β-galactopyranosyl-D-gluconic acid) is a sugar acid. It is a disaccharide formed from gluconic acid and galactose. It can be formed by oxidation of lactose. Lactobionic acid is also used in the cosmetics industry as an antioxidant and in the pharmaceutical industry as an excipient for formulation. Lactobionic acid is also used in preservation solutions for organ transplantation.
Specifications of Lactobionic Acid BP Ph Eur Grade
Ph Eur
C12H22O12 (acid form) -- 358.3 -- CAS 96-82-2
C12H20O11 (d-lactone) -- 340.3 -- CAS 5965-65-1DEFINITION
Mixture in variable proportions of 4-O-b-D-galactopyranosyl-D-gluconic acid and 4-O-b-Dgalactopyranosyl-D-glucono-1,5-lactone.
Content: 98.0 per cent to 102.0 per cent (anhydrous substance).CHARACTERS
Appearance: White or almost white powder.
Solubility: Freely soluble in water, slightly soluble in glacial acetic acid, in anhydrous ethanol and in methanol.
mp: About 125C with decomposition.IDENTIFICATION
A. Infrared absorption spectrophotometry.
Comparisonılactobionic acid CRS.
If the spectra obtained show differences, dissolve the substance to be examined and the reference substance separately in water, dry at 105C and record new spectra using the residues.
B. Thin-layer chromatography. To pass the test.TESTS
Appearance of solution: The solution is clear and not more intensely coloured than reference.
Specific optical rotation: + 23.0 to + 29.0 (anhydrous substance).
Dissolve 1.0 g in 80 ml of water and dilute to 100.0 ml with the same solvent. Allow to stand for 24 h.
Reducing sugars: Maximum 0.2 per cent, calculated as glucose.
Dissolve 5.0 g in 25 ml of water with the aid of gentle heat. Cool and add 20 ml of cupricitric solution and a few glass beads. Heat so that boiling begins after 4 min and maintain boiling for 3 min. Cool rapidly and add 100 ml of a 2.4 per cent V/V solution of glacial acetic acid and 20.0 ml of 0.025 M iodine. With continuous shaking, add 25 ml of a mixture of 6 volumes of hydrochloric acid and 94 volumes of water and, when the precipitate has dissolved, titrate the excess of iodine with 0.05 M sodium thiosulphate using 1 ml of starch solution, added towards the end of the titration, as indicator. Not less than 12.8 ml of 0.05 M sodium thiosulphate is required.
Heavy metals: Maximum 20 ppm.
Water: Maximum 5.0 per cent, determined on 0.50 g.
Total ash: Maximum 0.2 per cent.
Lactobionic Acid USP NF Grade:
C12H22O12 (acid form) --- 358.30 --- CASc96-82-2.
C12H20O11 (δ-lactone) 340.28 CAS 5965-65-1.
4-O-β-Galactopyranosyl-d-gluconic acid.DEFINITION
Lactobionic Acid is a mixture in variable proportions of 4-O-β-d-galactopyranosyl-d-gluconic acid and 4-O-β-d-galactopyranosyl-d-glucono-1,5-lactone. It contains 98% toT 102%, on the anhydrous basis.IDENTIFICATION
A. Infrared Absorption: [Note— If the spectra obtained show differences, dissolve the test substance and USP Lactobionic Acid RS separately in water, dry at 105C, and record new spectra using the residues. ]
B. Thin-Layer Chromatography: Acceptance criteria:The principal spot from the Sample solution is similar in position and color to the principal spot from the Standard solution.ASSAY
IMPURITIES
Procedure
Sample: 0.350 g of Lactobionic Acid
Analysis: Dissolve the Sample in 50 mL of carbon dioxide-free water, previously heated to 30C. Immediately titrate with 0.1 N sodium hydroxide and determine the two equivalence points potentiometrically.
Each mL of 0.1 N sodium hydroxide consumed to the first equivalency point is equivalent to 35.83 mg of C12H22O12 (corresponds to the acid form), and each mL of 0.1 N sodium hydroxide consumed between the first and second equivalency points is equivalent to 34.03 mg of C12H20O11 (corresponds to the δ-lactone form).
Calculate the content, expressed as a percentage, of the lactobionic acid as the sum of both results.
Acceptance criteria: 98.0%–102.0% on the anhydrous basis
Water Determination
Acceptance criteria: 5.0% maximum.
Appearance of Solution
Sample solution: 120 mg/mL of Lactobionic Acid
Standard stock solution: Pipet 24.0 mL of ferric chloride CS and 6.0 mL of cobaltous chloride CS into a 100-mL volumetric flask. Dilute with 1% (w/v) hydrochloric acid to volume.
Reference solution: Pipet 12.5 mL of the Standard stock solution into a 100-mL volumetric flask. Dilute with 1% (w/v) hydrochloric acid to volume.
Acceptance criteria: The Sample solution is clear and not more intensely colored than the Reference solution.
Optical Rotation
Sample solution: 10 mg/mL of Lactobionic Acid. Allow to stand for 24 h.
Acceptance criteria: +23.0° to +29.0° (anhydrous substance).
Reducing Sugars
Sample solution: Dissolve 5.0 g of Lactobionic Acid in 25 mL of water with the aid of gentle heat, and cool.
Analysis: To the Sample solution add 20 mL of cupric citrate TS and a few glass beads. Heat so that boiling begins after 4 min, and maintain boiling for 3 min. Cool rapidly, and add 100 mL of a 2.4% solution of glacial acetic acid and 20.0 mL of 0.025 M iodine VS. With continuous shaking, add 25 mL of a mixture of 6 mL of hydrochloric acid and 94 mL of water. When the precipitate has dissolved, titrate the excess iodine with 0.05 M sodium thiosulfate VS using 1 mL of starch TS, added toward the end of the titration as an indicator.
Acceptance criteria: NLT 12.8 mL of 0.05 M sodium thiosulfate is required, corresponding to NMT 0.2% of reducing sugars, as glucose.
Articles of Botanical Origin: 0.2% maximum.
The MSDS-SDS Hazard Statement of Lactobionic Acid:
Lactobionic Acid SDS GHS, Safety Data Sheet
MSDS, Material Safety Data Sheet 30-Jun-21Section 1: Chemical Product and Company Identification
Product Name & Other Names : Lactobionic Acid or 4-O-β-D-Galactopyranosyl-D-gluconic acid.
CAS Number: 96-82-2
EINECS EC Code: 202-538-3
Molecular Formula: C12 H22 O12
Molecular Weight: 358.29
Recommended usage: Industrial Manufacturing.
Suppliers: As per letterhead.Section 2: Hazards Identification
GHS, Globally Harmonized System Classification in accordance with 29 CFR 1910
Hazard Class and Category Code(s), Regulation (EC) No 1272/2008 (CLP)Not a hazardous substance or mixture according to Regulation (EC) No. 1272/2008.
This substance is not classified as dangerous according to Directive 67/548/EEC.Labeling Regulation as per GHS & EC 1272/2008 (CLP) & GHS
GHS Label Elements
NONESignal Word: None
Precautionary statements:
P261: Avoid breathing dust/fume/gas/mist/vapors/spray.
P262: Do not get in eyes, on skin, or on clothing.
P281: Use personal protective equipment as required.
P302+P352 - IF ON SKIN: Wash with plenty of soap and water.
P304 + P340 - IF INHALED: Remove victim to fresh air and keep at rest in a position comfortable for breathing.
P305 + P351 + P338 - IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
P337+313: If eye irritation persists get medical advice/attention.Section 3: Composition and Information on Ingredients
Product Name & Other Names: Lactobionic Acid or 4-O-β-D-Galactopyranosyl-D-gluconic acid.
CAS Number: 96-82-2
EINECS EC Code: 202-538-3Section 4: First Aid Measures
Always seek medical advice after the first aid treatment.
Skin: Rinse with water. Soap may be used. Seek Medical Aid.
Eyes: Wash eyes with plenty of water for at least 15 minutes, lifting lids occasionally. Seek Medical Aid.
Inhalation: Remove to fresh air. If not breathing, give artificial respiration. If breathing is difficult, give oxygen.
Ingestion: If swallowed, induce vomiting immediately after giving two glasses of water. Never give anything by mouth to an unconscious person.Section 5: Fire and Explosion Data
Flammability of the Product: Non-flammable. However, it can burn at higher temperatures.
Products of Combustion: Oxides of Carbon.
Fire Fighting Media and Instructions: Use water spray, alcohol-resistant foam, dry chemical, or carbon dioxide. Wear self-contained breathing apparatus for firefighting if necessary.
Extinguishing Media Not recommended: Avoid using solid water jet as it may scatter the fire.
Special Information: In the event of a fire, wear full protective clothing and NIOSH-approved self-contained breathing apparatus with full face piece operated in the pressure demand or other positive pressure mode. At high temperatures under fire conditions, it may produce toxic or irritating fumes. Fire-extinguishing work is done from the windward and the suitable fire-extinguishing method according to the surrounding situation is used. Uninvolved persons should evacuate to a safe place.Section 6: Accidental Release Measures
Personal precautions, protective equipment, and emergency procedures: Ventilate area of leak or spill. Avoid breathing dust/fumes/gas/mist/vapors/spray. Use individual protective equipment (waterproof boots, suitable protective clothing, safety glasses, etc.). Restrict unprotected personnel from the area. Prevent any contact with hot surfaces. Do not approach facing the wind. Do not touch the spilled material.
Environmental precautions: Do not let the product enter drains, soil, or water sources.
Methods and materials used for containment cleanup procedures and Storage: Contain spilled material. Cover with an inert, non-combustible absorbent material, (e.g., sand, earth, diatomaceous earth, vermiculite). Vacuum or sweep-up and remove to an approved disposal container. Finish cleaning by spreading water on the contaminated surface and allow to evacuate as per law.Section 7: Handling and Storage
Precautions for safe handling: Apply according to good manufacturing and industrial hygiene practices. Ensure proper ventilation. In case of insufficient ventilation, wear suitable respiratory equipment. Wash thoroughly after handling. Do not drink, eat, or smoke while handling. Avoid contact with skin, eyes, and clothing. Minimize dust generation. Avoid breathing dust/fumes/gas/mist/vapors/spray. Avoid contact with eyes, skin, and clothing. Keep container tightly closed. Avoid ingestion and inhalation. Use individual protective equipment (waterproof boots, suitable protective clothing, safety glasses, etc.). Prevent any contact with hot surfaces.
Conditions for safe storage, including any incompatibilities: Store in cool, dry, and ventilated area away from heat sources and protected from sunlight in tightly closed original container. Keep air contact to a minimum. Store protected from heat, sparks and ignition sources and incompatible materials. Avoid contact with skin and eyes. Avoid inhalation of dust/mist/vapor. Do not store with incompatible materials like strong oxidizing agents.Section 8: Exposure Controls/Personal Protection
Engineering Controls: Use process enclosures, local exhaust ventilation, or other engineering controls to keep airborne levels below recommended exposure limits. If user operations generate dust, fume, or mist, use ventilation to keep exposure to airborne contaminants below the exposure limit.
Ventilation System: A system of local and/or general exhaust is recommended to keep employee exposures as low as possible. Local exhaust ventilation is generally preferred because it can control the emissions of the contaminant at its source, preventing dispersion of it into the general work area.
Personal Respirators (NIOSH Approved): For conditions of use where exposure to dust or mist is apparent and engineering controls are not feasible, a particulate respirator may be worn. For emergencies or instances where the exposure levels are not known, use a full-face positive-pressure, air-supplied respirator.
Skin Protection: Wear protective gloves and clean body-covering clothing.
Eye Protection: Use chemical safety goggles and/or full-face shield where dusting or splashing of solutions is possible. Maintain eye wash fountain and quick-drench facilities in work area.
Other Control Measures: Maintain good housekeeping in work area. Dust deposits on floors and other surfaces may pick up moisture and cause the surfaces to become slippery and present safety hazards. Handle in accordance with good industrial hygiene and safety practice. Wash hands after handling.Section 9: Physical and Chemical Properties
Appearance: Solid. Off-white crystals powder or granules.
Odor: None.
Odor threshold: Not available.
pH (10% soln/water): 1.0-3.0.
Relative density: Not available.
Melting point/freezing point: 113 - 118C
Initial boiling point and boiling range: Not available.
Flash point: Not available.
Auto-ignition temperature: Not available.
Decomposition temperature: Not available.
Upper/lower flammability or explosive limits: Not available.
Vapor pressure: Not available.
Vapor density: Not available.
Evaporation rate: Not available.
Flammability (solid, gas): Not available.
Partition coefficient: n-octanol/water: Not available.
Solubility: Soluble in water.
Viscosity: Not available.
Molecular Formula: C12 H22 O12
Molecular Weight: 358.29Section 10: Stability and Reactivity Data
Stability: It is stable in room temperature in closed containers under normal storage & handling.
Conditions of instability: Incompatible materials, Moisture
Incompatibility with various substances: Avoid high temperatures, sparks, open flames, and moisture. Avoid contact with strong oxidizing agents.
Polymerization: Will not occur.Section 11: Toxicological Information
LD50 Oral - Rat - > 5,000 mg/kg(4-O-ß-D-galactopyranosyl-D-gluconic acid)
LD50 Dermal - Rat - > 2,000 mg/kg(4-O-ß-D-galactopyranosyl-D-gluconic acid)
Carcinogenicity: No component of this product present at levels greater than or equal to 0.1% is identified as possible or confirmed human carcinogen by IARC, ACGIH, OSHA and NTP.
Mutagenic Effects: Not available.
Teratogenic Effects: Not available.
Developmental Toxicity: Not available.
Reproductive Effects: No information available.Section 12: Ecological Information
Toxicity to fish: static test LC50 - Oncorhynchus mykiss (rainbow trout) - > 100 mg/l - 96 h(4-O-ß-D-galactopyranosyl-D-gluconic acid)
Results of PBT and vPvB assessment: This substance/mixture contains no components considered to be either persistent, bioaccumulative and toxic (PBT), or very persistent and very bioaccumulative (vPvB) at levels of 0.1% or higher.Section 13: Disposal Considerations
Waste Disposal: Waste must be disposed of in accordance with federal, state, and local environmental control regulations.
Section 14: Transport Information
Land Transport DOT USA, TDG Canada & ADR/RID Europe: Not dangerous goods.
Sea Transport IMDG/IMO: Not dangerous goods.
Air Transport IATA/ICAO: Not dangerous goods.Section 15: Other Regulatory Information
USA Regulations:
SARA 311/312 Hazard Categories: Not applicable. See section 2.
California Prop 65: California No Significant Risk Level: None of the chemicals in this product are listed.Section 16 - Additional Information
DISCLAIMER: The information and recommendations set forth herein (hereinafter "Information") are presented in good faith and believed correct as of the date hereof. It is compiled from various sources, and it is not necessarily all inclusive nor fully adequate in every circumstance. In addition, these suggestions should not be confused with nor followed in violation of applicable laws, regulations, rules, or insurance requirements applicable. This SDS MSDS sheet is intended only as a guide to the appropriate precautionary handling of the material by a professionally trained person using this product. Individuals receiving the information must exercise their independent judgment in determining its appropriateness for a particular purpose. This shall not constitute a guarantee for any specific product features and shall not establish a legally valid contractual relationship. In no case shall our company be liable to loss or damages by the product user.
Lactobionic Acid Manufacturers, Suppliers, Exporters, Wholesellers:
King of Chemicals manufacturers
Plot No. 2900/46&47 + 2900/163to167, GIDC, Ankleshwar, Dist. Bharuch, India
India, USA, UAE
TEL: (Office) 91-22-23774610, 91-22-23723564email: info@kingofchemicals.com
Copyright and Usual Disclaimer is Applicable --- October 25, 2024
If I give you “My Word” Nobody can undo it.
If I sign an “Agreement” my Lawyer will undo itOur products are for industrial and laboratory use only. The user must test the material before use. We are not dispensing chemists or druggist and do not offer over the counter type (OTC) products for medical use by individuals.
We and our associates manufacture pure chemicals surpassing Monograph Specifications of Analytical Reagent Standards, British & European Pharmacopoeia BP Ph Eur EP Standard, US Pharmacopoeia USP NF Standard, Indian Pharmacopoeia IP Standard, Japan Pharmacopoeia JP Standard, FCC Food Grade Standard.