Chemicals India USA UAE
King of Chemicals Manufacturers

Specifications, Properties, Uses, SDS of Meglumine or N-methyl d-glucamine or N-Methylglucamine or 1-Deoxy-1-(methylamino)-D-glucitol USP BP Ph Eur Grade Manufacturer Supplier Exporter Wholesale & Small Packs, CAS Number 6284-40-8.

King of Chemicals has several associated companies having accreditations like cGMP, GLP - FDA Approved Good Manufacturing Practice and Good Laboratory Practice of WHO standard, ISO-9001, ISO-14001, ISO/IEC 17025, ISO ISO-45000, HACCP, FSSC 220000, FSSAI, "REACH" Registered, Kosher & Halal Certified. e-CTD and DMF support can be made available if needed. We offer USP NF BP Ph Eur EP IP JP Analytical Reagent FCC Food Grade Chemicals & Nutraceuticals.
ISO 9001 ISO IEC 17025 GMP-Good Manufacturing Practice GLP Good Laboratory PracticeFSSCFSSAI Halal India Star Kosher India

Home ------ Contact

Muby Chem Pvt. Ltd. is a several decades old group of companies, engaged in manufacturing, supplying, distributing, wholesale supplies of Meglumine for actual users, including retail or small pack supplies for research and development work.

We supply fine and speciality chemicals, pharmaceutical excipients, mineral fortifiers in chemically pure, analytical reagent grade, IP BP USP Ph Eur EP JP and other pharmaceutical grade monograph including FCC Food grade chemicals and Nutraceuticals at best prices. We and/or our associated units have all the facilities to supply as per cGMP standard observing good manufacturing practice and good laboratory practice. We can assure low microbial count and also offer a test certificate for the same. We maintain warehouses across USA, India, and UAE. Our group exports to USA, Canada, Mexico, Argentina, Brazil, Chile, Korea, Malaysia, Thailand, Indonesia, Europe, and several other parts of the world. We supply in wholesale container loads to small pack of few grams. Solid products may be specified for it size and shape as desired by the buyer.

Exporters Urgent bag carboy Pallets IBC Jumbo Chemical Bottles

Meglumine Manufacturer Supplier Exporter
Meglumine or N-methyl d-glucamine or N-Methylglucamine or 1-Deoxy-1-(methylamino)-D-glucitol CAS Number 6284-40-8

For Properties Specifications Uses of Meglumine or N-methyl d-glucamine or N-Methylglucamine or 1-Deoxy-1-(methylamino)-D-glucitol Click Properties, Specifications, Uses, Price, Process of Meglumine  or N-methyl d-glucamine or N-Methylglucamine or 1-Deoxy-1-(methylamino)-D-glucitol Manufacturer.

For For SDS MSDS Sheet of Meglumine or N-methyl d-glucamine or N-Methylglucamine or 1-Deoxy-1-(methylamino)-D-glucitol Click SDS Safety Data Sheet MSDS Sheet of or N-methyl d-glucamine or N-Methylglucamine or 1-Deoxy-1-(methylamino)-D-glucitol Meglumine Manufacturer.

The Properties, Specifications, Monograph and Uses of Meglumine or N-methyl d-glucamine or N-Methylglucamine or 1-Deoxy-1-(methylamino)-D-glucitol:

Meglumine, USP is used as a functional excipient where it acts as a counterion to enhance API stability and solubility. 1. N-Methyl-D-glucamine or Meglumine can be used as a contrast agent and surfactant for medical use. It is also used as an excipient in pharmaceuticals, in cosmetics and X-ray contrast media. It is also employed in the synthesis of surface active agents, pharmaceuticals and dyes.Meglumine is a sugar alcohol derived from glucose that contains an amino group modification.

General Properties and Specifications of N-methyl d-glucamine or Meglumine or N-Methylglucamine or 1-Deoxy-1-(methylamino)-D-glucitol:
Appearance: White crystalline powder.
Purity: 99.0%-100.5%
Loss on drying: 1% maximum.
Residue on ignition: 0.1% maximum.
Heavy metals: 20 ppm maximum.
Melting point: 128C to 132C.
Solubility: Soluble in water.


Meglumine USP Grade Specifications:
C7H17NO5 --- 195.21
d-Glucitol, 1-deoxy-1-(methylamino)-;
1-Deoxy-1-(methylamino)-d-glucitol CAS 6284-40-8.

DEFINITION
Meglumine contains NLT 99.0% and NMT 100.5% of meglumine (C7H17NO5), calculated on the dried basis.

IDENTIFICATION
A
.
Sample solution: Transfer 250 mg to a dry, 50-mL centrifuge tube, add 500 mg of sodium metaperiodate, then add 5 mL of water rapidly in one portion. Allow to stand undisturbed.
Analysis: The solution instantly turns yellow, and heat is produced. The color then changes from deep yellow to orange-brown (rust), and after 20 min, the rust-colored solution is cloudy. Then add 2 mL of 2.5 N sodium hydroxide.
Acceptance criteria: The mixture turns bright yellow and becomes clear.

Residue on Ignition: NMT 0.1%
Absence of Reducing Substances
Sample solution: 50 mg/mL
Analysis: To 5 mL of Sample solution add 5 mL of alkaline cupric tartrate TS, and heat to boiling.
Acceptance criteria: The color of the solution does not change.
Completeness and Color of Solution: To pass the test.
Loss on Drying: NMT 1.0% at 105C to constant weight.
Melting Range or Temperature: 128C to 132C.
Optical Rotation, Specific Rotation:
Sample solution: 100 mg/mL, undried, in water.
Acceptance criteria: -15.7° to -17.3°
Packaging and Storage: Preserve in well-closed containers.


Meglumine BP Ph Eur Grade Specifications:
C7H17NO5 --- 195.2 --- CAS 6284-40-8
Action and use: Organic base used in the preparation of organic acids.

DEFINITION
1-Deoxy-1-(methylamino)-D-glucitol.
Content: 99.0 per cent to 101.0 per cent (dried substance).

CHARACTERS
Appearance: White or almost white, crystalline powder.
Solubility: Freely soluble in water, sparingly soluble in ethanol (96 per cent), practically insoluble in methylene chloride.
Mp: About 128C.

IDENTIFICATION
Infrared absorption spectrophotometry: Comparison meglumine CRS.

TESTS
Solution S: Dissolve 20.0 g in distilled water and dilute to 100.0 ;mL with the same solvent.
Appearance of solution: The solution is clear and its absorbance at 420 ;nm is not greater than 0.03.
Dissolve the residue obtained in the test for loss on drying in water and dilute to 10 mL with the same solvent.
Specific optical rotation: -16.0 to -17.0 (dried substance).
Reducing substances: Maximum 0.2 per cent, expressed as glucose.
Chlorides: Maximum 100 ppm.
Sulfates: Maximum 150 ppm.
Aluminium: Maximum 5 ppm.
Iron: Maximum 10 ppm.
Nickel: Maximum 5 ppm.
Sulfated ash: Maximum 0.1 per cent, determined on 1.0 g.
Bacterial endotoxins: Less than 1.5 IU/g, if intended for use in the manufacture of ;parenteral preparations without a further appropriate procedure for the removal of bacterial endotoxins.

The MSDS-SDS Hazard Statement of Meglumine or N-methyl d-glucamine or N-Methylglucamine or 1-Deoxy-1-(methylamino)-D-glucitol:

Meglumine or N-methyl d-glucamine or N-Methylglucamine or 1-Deoxy-1-(methylamino)-D-glucitol SDS, Safety Data Sheet
MSDS Sheet
19-Apr-22

Section 1: Chemical Product and Company Identification

Product Name & Other Names: Meglumine or N-methyl d-glucamine or N-Methylglucamine or 1-Deoxy-1-(methylamino)-D-glucitol.
CAS Number
: 6284-40-8
EINECS EC Code: 228-506-9
Molecular Formula: C7H17NO5
Molecular Weight: 195.21
Relevant uses and uses advised against (if any): Industrial Manufacturing.
Suppliers: As per letterhead.

Section 2: Hazards Identification

GHS, Globally Harmonized System Classification in accordance with 29 CFR 1910
Hazard Class and Category Code(s), Regulation (EC) No 1272/2008 (CLP)

Not a hazardous substance or mixture according to Regulation (EC) No. 1272/2008.
This substance is not classified as dangerous according to Directive 67/548/EEC.

Labeling Regulation EC 1272/2008 (CLP) & GHS

GHS Label Elements
NONE

Signal Word: None

Precautionary statements:
P261: Avoid breathing dust/fume/gas/mist/vapors/spray.
P262: Do not get in eyes, on skin, or on clothing.
P281: Use personal protective equipment as required.
P302+P352 - IF ON SKIN: Wash with plenty of soap and water.
P304 + P340 - IF INHALED: Remove victim to fresh air and keep at rest in a position comfortable for breathing.
P305 + P351 + P338 - IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
P337+313: If eye irritation persists get medical advice/attention.

Section 3: Composition and Information on Ingredients

Product Name & Other Names: Meglumine or N-methyl d-glucamine or N-Methylglucamine or 1-Deoxy-1-(methylamino)-D-glucitol.
CAS Number
: 6284-40-8
EINECS EC Code: 228-506-9

Section 4: First Aid Measures

Always seek medical advice after the first aid treatment.

Skin: Rinse with water. Soap may be used. Seek Medical Aid.
Eyes: Wash eyes with plenty of water for at least 15 minutes, lifting lids occasionally. Seek Medical Aid.
Inhalation: Remove to fresh air. If not breathing, give artificial respiration. If breathing is difficult, give oxygen.
Ingestion: If swallowed, induce vomiting immediately after giving two glasses of water. Never give anything by mouth to an unconscious person.

Section 5: Fire and Explosion Data

Flammability of the Product: Flammable in high concentration of dust in air.
Products of Combustion: Carbon oxides, Nitrogen oxides (NOx) and fumes.
Fire Fighting Media and Instructions: Use water spray, alcohol-resistant foam, dry chemical, or carbon dioxide. Use extinguishing measures that are appropriate to local circumstances and the surrounding environment. Wear self-contained breathing apparatus for firefighting if necessary.
Extinguishing Media Not recommended: Avoid using solid water jet as it may scatter the fire.
Special Information: In the event of a fire, wear full protective clothing and NIOSH-approved self-contained breathing apparatus with full face piece operated in the pressure demand or other positive pressure mode. At elevated temperatures under fire conditions, it may produce toxic or irritating fumes. Fire-extinguishing work is done from the windward and the suitable fire-extinguishing method according to the surrounding situation is used. Uninvolved persons should evacuate to a safe place.

Section 6: Accidental Release Measures

Personal precautions, protective equipment, and emergency procedures: Avoid breathing dust/fumes/gas/mist/vapors/spray. Use individual protective equipment (waterproof boots, suitable protective clothing, safety glasses, etc.). Prevent any contact with hot surfaces. Do not approach facing the wind. Do not touch the spilled material.
Environmental precautions: Do not let the product enter drains, soil, or water sources.
Methods and materials used for containment cleanup procedures and Storage: Contain spilled material. Do not inhale vapors, mist, or gas. Avoid dust formation. Use a shovel to put the material into a convenient waste disposal container. Finish cleaning by spreading water on the contaminated surface and dispose as per law.

Section 7: Handling and Storage

Precautions for safe handling: Apply according to good manufacturing and industrial hygiene practices. Ensure proper ventilation. Wash thoroughly after handling. Do not drink, eat, or smoke while handling. Avoid contact with skin, eyes, and clothing. Minimize dust generation. Avoid breathing dust/fumes/gas/mist/vapors/spray. Use individual protective equipment (waterproof boots, suitable protective clothing, safety glasses, etc.). Prevent any contact with hot surfaces.
Conditions for safe storage, including any incompatibilities: Store in cold, dry, and ventilated area away from heat sources and protected from sunlight in tightly closed original container. Keep air contact to a minimum. Do not leave the material container open. Store protected from heat, sparks and ignition sources and incompatible materials. Do not store with incompatible materials like oxidizing agents. Hygroscopic. Air sensitive.

Section 8: Exposure Controls/Personal Protection

Exposure Guidelines: This product, as supplied, does not contain any hazardous materials with occupational exposure limits established by the region-specific regulatory bodies.
Engineering Controls: Use process enclosures, local exhaust ventilation, or other engineering controls to keep airborne levels below recommended exposure limits. If user operations generate dust, fume, or mist, use ventilation to keep exposure to airborne contaminants below the exposure limit.
Engineering Controls: Showers, Eyewash stations and Ventilation systems
Ventilation System: A system of local and/or general exhaust is recommended to keep employee exposures as low as possible. Local exhaust ventilation is preferred because it can control the emissions of the contaminant at its source, preventing dispersion of it into work area.
Personal Respirators (NIOSH Approved): For conditions of use where exposure to dust or mist is apparent and engineering controls are not feasible, a particulate respirator may be worn. For emergencies or instances where the exposure levels are not known, use a full-face positive-pressure, air-supplied respirator.
Skin Protection: Wear protective gloves and clean body-covering clothing.
Eye Protection: Use chemical safety goggles and/or full-face shield where dusting or splashing of solutions is possible. Maintain eye wash fountain and quick-drench facilities in work area.
Other Control Measures: Maintain good housekeeping in work area. Dust deposits on floors and other surfaces may pick up moisture and cause the surfaces to become slippery and present safety hazards. Handle in accordance with good industrial hygiene and safety practice.

Section 9: Physical and Chemical Properties

Physical state and appearance: White crystalline powder.
Odor: Not available.
Odor threshold: Not available.
pH (5% soln/water): Not available.
Relative density: Not available.
Melting point/freezing point: 128C to 132C.
Initial boiling point and boiling range: Not available.
Flash point: Not available.
Auto-ignition temperature: Not available.
Decomposition temperature: Not available.
Upper/lower flammability or explosive limits: Not available.
Vapor pressure: Not available.
Vapor density: Not available.
Evaporation rate: Not available.
Flammability (solid, gas): Not available.
Partition coefficient: n-octanol/water: Not available.
Solubility: Soluble in water. Sparingly soluble in ethanol (96 per cent). Practically insoluble in methylene chloride.
Viscosity: Not available.
Molecular Formula: C7H17NO5
Molecular Weight: 195.21

Section 10: Stability and Reactivity Data

Stability: It is stable in room temperature in closed containers under normal storage & handling.
Conditions of instability: Incompatible materials, Moisture. Hygroscopic. Air sensitive.
Incompatibility with various substances: Avoid elevated temperatures, sparks, open flames. Avoid contact with strong oxidizing agents.
Polymerization: Will not occur.

Section 11: Toxicological Information

LD50 Oral Rat: >5000 mg/kg.
LD50 Oral Rabbit: >5000 mg/kg.
Carcinogenic Effects: Not a reported carcinogen by IARC, NTP, ACGIH, OSHA.
Mutagenic Effects: Not available.
Developmental Toxicity: Not available.
Reproductive Effects: No information available.

Section 12: Ecological Information

Toxicity to fish: Not available.
Persistence and Degradability: It is expected to be degradable.
Mobility: Likely to be mobile.
Results of PBT and vPvB assessment: No data available for assessment.

Section 13: Disposal Considerations

Waste Disposal: Waste must be disposed of in accordance with federal, state, and local environmental control regulations.

Section 14: Transport Information

Land Transport DOT USA, TDG Canada & ADR/RID Europe: Not Regulated.
Sea Transport IMDG/IMO: Not Regulated.
Air Transport IATA/ICAO: Not Regulated.

Section 15: Other Regulatory Information

USA Regulations:
SARA 311/312: See section 2.
California Prop 65: None of the chemicals in this product are listed.

Section 16 - Additional Information

Disclaimer:
Our company provides this SDS information contained herein in good faith but makes no representation as to its comprehensiveness or accuracy. This MSDS sheet is intended only as a guide to the appropriate precautionary handling of the material by a professionally trained person using this product. Individuals receiving the information must exercise their independent judgment in determining its appropriateness for a particular purpose.

Muby Chem P Ltd

Meglumine or N-methyl d-glucamine or N-Methylglucamine or 1-Deoxy-1-(methylamino)-D-glucitol Manufacturers, Suppliers, Exporters, Wholesalers:

King of Chemicals manufacturers

Muby Chem Private Limited
Plot No. 2900/46&47 + 2900/163to167, GIDC, Ankleshwar, Dist. Bharuch, India
India, USA, UAE
TEL: (Office) 91-22-23774610, 91-22-23723564

e-mail: info@kingofchemicals.com

Copyright and Usual Disclaimer is Applicable --- October 26, 2024

If I give you “My Word” Nobody can undo it.
If I sign an “Agreement” my Lawyer will undo it

Our products are for industrial and laboratory use only. The user must test the material before use. We are not dispensing chemists or druggist and do not offer over the counter type (OTC) products for medical use by individuals.

We and our associates manufacture pure chemicals surpassing Monograph Specifications of Analytical Reagent Standards, British & European Pharmacopoeia BP Ph Eur EP Standard, US Pharmacopoeia USP NF Standard, Indian Pharmacopoeia IP Standard, Japan Pharmacopoeia JP Standard, FCC Food Grade Standard.

Dihydroxy-aluminum Aminoacetate

Gluconolactone

D-Glucurono-lactone

Meglumine

Tert Butyl Hydroquinone TBHQ